Abstract Details

Opportunistic measurement of Flash Visual Evoked Potentials using routinely collected EEG data: a feasibility study applied to Progressive Myoclonic Epilepsy

Visual Evoked Potentials (VEPs) are useful in diagnosing and monitoring a range of conditions, including Multiple Sclerosis, optic neuritis and vision impairment. They have also been investigated as a diagnostic tool in the Epilepsies. So-called “giant” VEPs (potentials well exceeding the expected level) have been noted in intracranial hypertension, and in epilepsy or other myoclonic disorders.  It has been particularly observed that they may occur in a rare but devastating subgroup of Epilepsy, the progressive myoclonic epilepsies (PMEs), which are unusual in that they are characterised by the accumulation of intellectual disability and increasing seizure burden.

Measuring VEPs may be useful in aiding more rapid diagnosis of these conditions, especially as for some subtypes of PME gene therapies are available or in development. Measuring VEPs– however – is not routinely performed.
We explored the possibility of using EEG data acquired routinely during photic stimulation to compute pragmatic VEPs from patients. We applied this technique to individuals with PME, including a large cohort of individuals with MERRF – a rare PME caused by mitochondrial disease.

We used the MNE-Python library to extract VEPs from previously recorded EEG data with photic stimulation (using a Natus xltek EEG32U system). In brief, these were measured from the occipital electrodes O1 and O2 to Fz, and VEP magnitudes were calculated from averaged responses across all photic frequencies. This technique was applied to 106 adult patients who had attended a tertiary neurology centre for evaluation of first seizures, or monitoring of non-PME epilepsy. We also calculated VEPs for 4 patients with a diagnosis of Neuronal Ceroid Lipofuscinosis (a subtype of PME believed to feature giant VEPs) and 24 patients with MERRF. We validated the derived EEG VEPs by comparing these with formal flash VEPs acquired on a Cadwell Industries Sierra Summit configured for recording flash VEPs in a small cohort of healthy controls.

We identified “giant” VEPs in 2 of our 4 NCL patients, and in none of our MERRF patients (a finding supported by a previous study). 10 individuals in the non-PME cohort had calculated VEPs lying outside 1.5x the interquartile range. We found our pragmatic method yielded acceptably similar VEP measurements to a formal assessment for screening purposes.

Pragmatic opportunistically measured VEPs may provide added information in the assessment of routine EEG, and may prompt further assessment where giant VEPs are suspected – this would speed diagnosis and potentially access to disease modifying treatment.

TitleForenamesSurnameInstitutionLead AuthorPresenter
DrThomas BruceAtkinsonThe Newcastle upon Tyne Hospitals NHS Foundation Trust/Newcastle University
MsKateWilkinsonThe Newcastle upon Tyne Hospitals NHS Foundation Trust
MsAnitaJhajThe Newcastle upon Tyne Hospitals NHS Foundation Trust
DrStuartMaitlandThe Newcastle upon Tyne Hospitals NHS Foundation Trust/Newcastle University
ProfMark R.BakerThe Newcastle upon Tyne Hospitals NHS Foundation Trust/Newcastle University
Reference
So, N., Berkovic S., Andermann F., Kuzniecky, R., Gendron, D. and Quesney L. F. (1989) ‘ Myoclonus epilepsy and ragged-red fibres (MERRF). 2. Electrophysiological studies and comparison with other progressive myoclonus epilepsies’: Brain, 112 (5) pp. 1261-79
Trivisano, M. et al. (2022) 'Neurophysiological Findings in Neuronal Ceroid Lipofuscinoses': Front Neurol., 13.